Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Users Online: 712

 

Home  | About Us | Editors | Search | Ahead Of Print | Current Issue | Archives | Submit Article | Instructions | Subscribe | Contacts | Login 
     


 
 
Table of Contents
LETTER TO THE EDITOR
Year : 2016  |  Volume : 6  |  Issue : 4  |  Page : 211-212

The importance of chest X-ray during nasogastric tube insertion


1 Department of Abdominal Surgery, Vladimir City Clinical Hospital of Emergency Medicine, Vladimir, Russia
2 Department of Surgery, North-Western State Medical University, St. Petersburg, Russia
3 Department of ICU and Anaesthesiology, Vladimir City Clinical Hospital of Emergency Medicine, Vladimir, Russia

Date of Web Publication8-Dec-2016

Correspondence Address:
Mahir Gachabayov
Department of Abdominal Surgery, Vladimir City Clinical Hospital of Emergency Medicine, 6-73, Stavrovskaya Street, Vladimir 600022
Russia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2229-5151.195453

Rights and Permissions

How to cite this article:
Gachabayov M, Kubachev K, Neronov D. The importance of chest X-ray during nasogastric tube insertion. Int J Crit Illn Inj Sci 2016;6:211-2

How to cite this URL:
Gachabayov M, Kubachev K, Neronov D. The importance of chest X-ray during nasogastric tube insertion. Int J Crit Illn Inj Sci [serial online] 2016 [cited 2020 Feb 23];6:211-2. Available from: http://www.ijciis.org/text.asp?2016/6/4/211/195453

Dear Editor,

We read the paper by Stawicki and Deb on the bronchial nasoenteric tube misplacement with great interest, for what we would like to extend our thanks. [1] Nasogastric tube (NGT) or nasoenteric tube misplacement and complications related to them are almost always preventable issues. Despite the presence of various radiologic and endoscopic facilities, NGT-related complications are still present. The question is to recognize when, in which case, and for what signs and symptoms to use them. We would like to share another case of bronchial NGT misplacement.

A 49-year-old female patient with chronic renal failure corrected by dialysis was admitted with a 3-day history of abdominal pain. After physical and instrumental examinations, the patient was diagnosed with complicated acute appendicitis, for which open appendectomy was performed. Since the approach was gridiron incision, intraoperative manual control was impossible. The patient was transferred to the Intensive Care Unit postoperatively because of severe chronic disease and sepsis. On the 1 st postoperative day, after extubation, the patient developed postoperative ileus, for what it was decided to insert a double lumen NGT. During NGT insertion at 30-35 cm, resistance was encountered. Chest X-ray was performed which revealed the tip of the NGT to be in the right superior lobar bronchus [Figure 1]. The tube was withdrawn and readvanced without any resistance. On control chest X-rays, no delayed complications were revealed. The postoperative course was uneventful and the patient was discharged on the 7 th postoperative day. On the follow-up after a month, the patient was well.
Figure 1: Chest X-ray. Nasogastric tube misplacement to the right superior lobar bronchus

Click here to view


In the treatment of postoperative ileus, NGT is one of the most effective measures. However, NGT placement in rare cases, especially in nonexperienced hands, can lead to specific serious complications, such as bronchial misplacement, lung perforation, esophageal perforation, pneumonia, and pneumothorax. [2] Several techniques and diagnostic measures have been reported, such as the SORT maneuver which is the mnemonic for the four main steps constituting the technique: sniffing position, NGT orientation, contralateral rotation, and twisting movement. [3] In the systematic review, Bennetzen et al. found Level 2B evidence for colorimetric capnography as an accurate method for verifying NGT placement with the sensitivity and specificity reaching 100%, nevertheless, with a concern that capnographs are not manufactured specifically to fit NGT and they have to be connected to the NGT by an adaptor system. [4] Despite the diversity of methods facilitating NGT placement, chest X-ray remains the gold standard. It is worth emphasizing that for experienced physicians, the most reliable way is clinical signs and symptoms and physical examination (auscultation) with the main rule "Do not proceed if you encountered resistance." And this is probably the point when instrumental methods could be involved. In surgical practice, the best and the most accurate method is intraoperative NGT insertion with manual control.

To conclude, NGT tube placement can lead in rare cases to serious complications. In case if resistance is faced during the first attempt, chest X-ray should be performed. If during subsequent attempts resistance is encountered, other navigating or guiding diagnostic methods should be utilized.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Stawicki SP, Deb L. Bronchial nasoenteric tube misplacement: Effective prevention, prompt recognition, and patient safety considerations. Int J Crit Illn Inj Sci 2016;6:156-160.  Back to cited text no. 1
[PUBMED]  Medknow Journal  
2.
Gupta PK, Gupta K, Jain M, Garg T. Postprocedural chest radiograph: Impact on the management in critical care unit. Anesth Essays Res 2014;8:139-44.  Back to cited text no. 2
  Medknow Journal  
3.
Najafi M. Nasogastric tube insertion easily done: The SORT maneuver. Indian J Crit Care Med 2016;20:492-3.  Back to cited text no. 3
[PUBMED]  Medknow Journal  
4.
Bennetzen LV, Håkonsen SJ, Svenningsen H, Larsen P. Diagnostic accuracy of methods used to verify nasogastric tube position in mechanically ventilated adult patients: A systematic review. JBI Database System Rev Implement Rep 2015;13:188-223.  Back to cited text no. 4
    


    Figures

  [Figure 1]


This article has been cited by
1 Chest radiographs of cardiac devices (Part 1): Lines, tubes, non-cardiac medical devices and materials
Rishi P. Mathew,Timothy Alexander,Vimal Patel,Gavin Low
South African Journal of Radiology. 2019; 23(1)
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed1276    
    Printed15    
    Emailed0    
    PDF Downloaded64    
    Comments [Add]    
    Cited by others 1    

Recommend this journal