Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Users Online: 465

 

Home  | About Us | Editors | Search | Ahead Of Print | Current Issue | Archives | Submit Article | Instructions | Subscribe | Contacts | Login 
     


 
 
Table of Contents
LETTER TO THE EDITOR
Year : 2015  |  Volume : 5  |  Issue : 3  |  Page : 218-219

Hypercapnia during endoscopic saphenectomy complicating CABG


1 Deparatment of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA
2 Deparatment of Anesthesiology, Houston Methodist Hospital, Houston, Texas, USA

Date of Web Publication10-Sep-2015

Correspondence Address:
Thomas J Papadimos
Department of Anesthesiology, The Ohio State University Wexner Medical Center, Columbus, Ohio
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2229-5151.165014

Rights and Permissions

How to cite this article:
Bhandary SP, Essandoh M, Karri S, Papadimos TJ. Hypercapnia during endoscopic saphenectomy complicating CABG. Int J Crit Illn Inj Sci 2015;5:218-9

How to cite this URL:
Bhandary SP, Essandoh M, Karri S, Papadimos TJ. Hypercapnia during endoscopic saphenectomy complicating CABG. Int J Crit Illn Inj Sci [serial online] 2015 [cited 2021 Aug 2];5:218-9. Available from: https://www.ijciis.org/text.asp?2015/5/3/218/165014

Dear Editor,

A 69-year-old, 179 cm, 101 kg male, with coronary artery disease, ischemic cardiomyopathy and a 25% ejection fraction, underwent coronary artery bypass grafting (CABG). Past medical history included hypertension, hyperlipidemia, pulmonary fibrosis, and stroke. Anesthetic induction was uneventful. Anesthesia was maintained with isoflurane in 100% oxygen. Monitoring included standard ASA monitors, invasive arterial blood pressure, pulmonary artery catheter placement, transesophageal echocardiography, and foley catheter.

The baseline arterial blood gas (ABG) was pH 7.343, PaCO 2 was 30.6 mmHg, PaO 2 was 86.6 mmHg, bicarbonate 16.2 mM/L, and potassium 4.7 mM/L on FiO 2 1.0 on SIMV 10, Tidal Volume (TV) 700 ml, peep 5 cm H 2 O and pressure support 5 cm H 2 O and minute ventilation (MV) 6 L/min. Median sternotomy incision was made concurrently with endoscopic saphenous vein harvesting using carbon dioxide insufflation (initiated flow of 3 L/min with insufflation pressure of 12 mmHg-normal flow rate and pressure). End-tidal CO 2 progressively increased during the harvest (over 45 minutes). A follow-up ABG demonstrated a pH of 7.11, PaCO 2 66.8 mmHg, PaO 2 248 mmHg, bicarbonate 20.3 mM/L, potassium 5.5 mM/L. MV was increased to 12 L/min with a resultant ABG of pH 7.15, PaCO 2 56.6 mmHg, PaO 2 263 mmHg, bicarbonate 19.3 mM/L, and potassium 5.6 mM/L.

The MV was eventually adjusted to 20 L/min with a consequent ABG of pH 7.11, PaCO 2 65.1 mmHg, PaO 2 250 mmHg, and bicarbonate 19.9 mM/L. The heart rate reached 120 beats/min and the blood pressure was as low as 90/60 mm Hg. Pulmonary artery pressure increased from 40/20 mmHg to 50/30 mm Hg. Urine output remained unaffected and the patient remained afebrile.

There was no evidence of increased bleeding, vessel injury or equipment malfunction. Transesophageal echocardiography revealed no abnormalities. When the saphenectomy was completed, and insufflation discontinued, the acidemia resolved (over 90 minutes). The saphenectomy time was prolonged at 59 minutes and the surgery was completed uneventfully. The patient was transferred to the intensive care unit (ICU) and extubated on post-operative day one and discharged on the sixth day.

The prolonged saphenectomy time contributed to the hypercapnea. Additionally, a sealed anesthesia system was used as opposed to an open system, and this too may have contributed to the hypercapnea/acid base disorder. Endoscopic saphenectomy is an alternative to conventional open vein vessel harvesting. Its advantages include better wound healing, reduced pain and better cosmesis. Endoscopy with carbon dioxide insufflation allows better operative field visualization and easier tissue plane identification, and improved hemostasis without needing retraction. [1]

This technique's disadvantages, besides hypercapnea with hemodynamic perturbations, include CO 2 embolization through a patent foramen ovale, as well as occasional poor visibility which requires increased insufflation pressures thereby allowing CO 2 circulatory access. [2],[3]

Several differential diagnoses need consideration, including lighter planes of anesthesia, malignant hyperthermia, thyroid storm, and neurolept malignant syndrome. Endoscopic saphenectomy associated with hypercapnea secondary to CO 2 insufflation during venous conduit acquisition is rare. We report this case to our colleagues in order to demonstrate the importance of vigilance on the surgeon/anesthesiologist's part in regard to the occurrence and differential diagnosis of hypercapnea in this setting.

 
   References Top

1.
Dalrymple-Hay MJ, ALzetani A, Costa R, Ohri SK. Endoscopic vein harvesting with the aid of carbon dioxide insufflation. Ann Thorac Surg 2001;71:739-41.  Back to cited text no. 1
    
2.
BanksTA, Manetta F, GLick M, Graver LM. Carbon dioxide embolism during minimally invasive vein harvesting. Ann Thorac Surg 2002;73:296-7.  Back to cited text no. 2
    
3.
Tami, M, Omrani M, Tash A, El Watidy A. Carbon dioxide embolism during endoscopic vein harvesting. Interact Cardiovasc Thorac Surg 2008;7:659-60.  Back to cited text no. 3
    




 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References

 Article Access Statistics
    Viewed1843    
    Printed28    
    Emailed0    
    PDF Downloaded30    
    Comments [Add]    

Recommend this journal